TM 9-2320-440-13&P
0039-3
0039
MRP LOCKS DO NOT DISENGAGE (CONTINUED)
THAAD0627
NOTE
•
MRP elevation cylinders must be in fully stowed position to disengage rack locks.
•
MRP present proximity switches must be active to engage MRP rack locks.
If MRP rack
is not loaded, activate both MRP present proximity switches by placing metal objects over
proximity switches while engaging MRP rack locks.
Step 3.
Check if left and right elevation cylinders are in there stowed position.
a.
If elevation cylinders are not stowed and MRP rack is loaded, start
engine (
stow left and right elevation cylinders
(WP 0007) and go to Step 4.
b.
If elevation cylinders are not stowed and MRP rack is not loaded, stow
left and right elevations cylinders using bypass procedure (WP 0139)
and go to Step 4.
c.
If elevation cylinders are stowed, go to Step 4.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TM 9-2320-347-10)