TM-9-2320-440-13-P

TERMINAL HIGH ALTITUDE AREA DEFENSE (THAAD) CARRIER

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST)

AUGUST 2010

  TM-9-2320-440-13-P - Page 389 of 1616

TM 9-2320-440-13&P
0039-9
0039
MRP LOCKS DO NOT DISENGAGE (CONTINUED)
THAAD0688
WARNING
Remove rings, wristwatches, neck chains, and any other jewelry before working
around vehicle.
Jewelry can catch on equipment and cause serious injury.
Jewelry
and tools may short across electrical circuits and cause damage to equipment or
severe burns or electrical shock to personnel.
Step 12.
Disconnect THAAD control valve harness VIM No. 2, 40 pin connector (WP 0089).
Check for continuity from wire 1963 at VIM No. 2, 40 pin connector, terminal 35 to a
known good ground.
If there is no continuity, go to Step 19.
Step 13.
Check for continuity from wire 1964 at THAAD control valve harness VIM No. 2, 40 pin
connector, terminal 36 to a known good ground.
If there is no continuity, go to Step 24.
Step 14.
Soldier A checks for continuity from wire 1957 at THAAD control valve harness VIM No.
2, 40 pin connector, terminal 38 to a known good ground, while Soldier B presses MRP
palm button switch (WP 0012).
If there is no continuity, go to Step 27.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION


Back to Top