TM 9-2320-440-13&P
0059-1
0059
FIELD LEVEL MAINTENANCE
BATTERIES, TERMINALS, AND CABLES REPLACEMENT
INITIAL SETUP:
REMOVAL
WARNING
Batteries produce explosive gases.
To prevent injury to personnel, keep sparks
and flames away, and do not smoke near batteries.
1.
Release two rubber hooks (1) and remove battery box cover (2) from battery box (3).
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
THAAD0011
Tools and Special Tools
Tool Kit, General Mechanic’s: Automotive
(WP 0183, Item 25)
Wrench, Torque (WP 0183, Item 30)
Materials/Parts
Compound, Corrosion Preventive (WP 0186,
Item 10)
Lockwasher, (4), (WP 0184, Item 59)
Lockwasher, (4), (WP 0184, Item 142)
Tags, Identification (WP 0186, Item 32)
Ties, Cable, Plastic (WP 0186, Item 34)
Personnel Required
MOS 63B Wheeled vehicle mechanic (3)
References
None
Equipment Conditions
Engine OFF (
TM 9-2320-347-10)