12. Remove wires 1461 (35), 1435 (36), 1435 (37), 1469 (38), 1466 (39), 1470 (40), and 1475 (41) from terminal
strip (7).
13. Remove two locknuts (42), screws (43), and terminal strip (7) from junction box (3). Discard locknuts.
14. Remove four locknuts (44), bulkheads (45) and O-rings (46) from junction box (3). Discard locknuts and O-
rings.
15. Remove four locknuts (47), screws (48), connector (32), and harness (49) from junction box (3). Discard
locknuts.
END OF TASK
INSTALLATION
WARNING
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful
vapors, and are harmful to skin and clothing.
To avoid injury or death, keep away
from open fire and use in a well-ventilated area.
If adhesive, solvent, or sealing
compound gets on skin or clothing, wash immediately with soap and water.
NOTE
Install cable ties as required.
1.
Apply adhesive to back of connector (32) and install harness (49) and connector (32) in junction box (3) with
four screws (48) and locknuts (47).
2.
Install four bulkheads (45) and O-rings (46) on junction box (3) with four locknuts (44).
3.
Apply adhesive to back plate of terminal strip (7) and install terminal strip (7) on junction box (3) with two
screws (43) and locknuts (42).
4.
Install wires 1475 (41), 1470 (40), 1466 (39), 1469 (38), 1435 (37), 1435 (36), and 1461 (35) on terminal
strip (7).
THAAD0406