4-68. POWER CABLE ENTRANCE PORT MAINTENANCE (M447,M447C, AND M750).
This Task Covers:
Removal
c.
Installation
Inspection and Repair
Initial Setup:
Tools/Test Equipment:
General mechanic’s
References:
tool kit
FM 10-16
1.
Working inside semitrailer, remove six screws (1) securing spacer plate (2) and cover (8) to left rear wall (3).
Remove spacer plate and cover.
2.
Working outside semitrailer, remove cap (7) from adapter (4).
3.
Remove six screws (9) and adapter (4) from left rear wall (3).
4.
If cap (7) or chain
(6)
are
(3).
remove screw (5) from chain and remove cap and chain from left rear wall
TA702030