TM-9-2330-330-14-P

SEMITRAILER, FUEL TANKER: 5000-GALLON, FUEL-DISPENSING, AUTOMOTIVE, M969A3

TECHNICAL MANUAL; OPERATOR’S, ORGANIZATIONAL, DIRECT SUPPORT, AND GENERAL SUPPORT MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST)

NOVEMBER 2005

  TM-9-2330-330-14-P - Page 113 of 1116

TM 9-2330-330-14&P
0011 00-1
ENGINE TROUBLESHOOTING
0011 00
THIS WP COVERS:
Engine Troubleshooting
INITIAL SETUP:
Maintenance Level
References
Operator/Crew
WP 0035 00
WP 0039 00
To troubleshoot the M969A3 engine, perform the test/inspections and corrective actions provided in
Table 1.
Table 1. Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
ENGINE WILL NOT TURN
OVER
1.
Set engine switch on
control panel to RUN and
check battery voltage
gage.
If battery voltage gage indicates
less than 24–28 V dc, notify
Organizational maintenance. If
battery gage voltage is okay, go
to step 2.
2.
ENGINE IS HARD TO
START OR TURNS OVER
SLOWLY
2.
Remove battery cover and
check for loose, frayed, or
corroded battery cable
connections.
3.
Remove vent fill caps from
batteries and check for low
electrolyte.
1.
Set engine switch on
control panel to RUN and
check battery voltage
gage.
2.
Remove battery cover and
check for loose, frayed, or
corroded battery cable
connections.
If cables are corroded, frayed, or
broken, notify Organizational
maintenance. If cables are okay,
go to step 3.
If electrolyte is low, notify
Organizational maintenance.
If battery voltage gage indicates
less than 24–28 V dc, notify
Organizational maintenance. If
battery voltage gage is okay, go
to step 2.
If cables are corroded, frayed, or
loose, notify Organizational
maintenance. If cables are okay,
go to step 3.


Back to Top