0014 00-1
FUEL SYSTEM TROUBLESHOOTING
0014 00
THIS WP COVERS:
Fuel System Troubleshooting
INITIAL SETUP:
Maintenance Level
References
Operator/Crew
WP 0006 00
WP 0040 00
WP 0007 00
WP 0041 00
To troubleshoot the M969A3 fuel system, perform the test/inspections and corrective actions provided in
Table 1.
Table 1. Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
FUEL DOES NOT FLOW
DURING ANY FUEL
SERVICING OPERATION
1.
Verify fuel in tank.
If tank has fuel, go to step 2. If
tank has no fuel, fill tanker. Verify
problem is solved.
2.
Verify all valves are set per
fuel operations schematic
on tool box lid (refer to
WP 0007 00).
3.
Check pump strainer for
debris or dirt clogging inlet.
4.
Check for debris or dirt in
nozzle screen of quick
coupling.
5.
Verify emergency valve A
control handle is in open
position.
Set valves per schematic on tool
box lid (refer to WP 0007 00). If
valves are already set per fuel
operations schematic, go to
step 3.
Clean strainer per WP 0041 00.
Verify problem is solved. If
screen was not clogged, go to
step 4.
If dirt or debris are present in
nozzle screen, clean screen per
WP 0041 00. Verify problem is
solved. If dirt and debris are not
present, go to step 5.
If valve is not in the open
position, open valve. Verify
problem is solved. If valve is
already open, notify
Organizational maintenance that
further troubleshooting is
required.