TM-9-2330-330-14-P

SEMITRAILER, FUEL TANKER: 5000-GALLON, FUEL-DISPENSING, AUTOMOTIVE, M969A3

TECHNICAL MANUAL; OPERATOR’S, ORGANIZATIONAL, DIRECT SUPPORT, AND GENERAL SUPPORT MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST)

NOVEMBER 2005

  TM-9-2330-330-14-P - Page 117 of 1116

TM 9-2330-330-14&P
0012 00-1/2 blank
ELECTRICAL SYSTEM TROUBLESHOOTING
0012 00
THIS WP COVERS:
Electrical System Troubleshooting
INITIAL SETUP:
Maintenance Level
Operator/Crew
To troubleshoot the M969A3 electrical system, perform the test/inspections and corrective actions
provided in Table 1.
Table 1. Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
LIGHTS ON TRAILER
WILL NOT OPERATE
1.
Check switch on prime
mover (refer to applicable
prime mover TM) is in the
ON position.
If taillights do not operate
properly, go to step 2.
2.
ONE OR MORE LIGHTS
(BUT NOT ALL) WILL
NOT OPERATE, OR
LIGHTS ARE DIM OR
FLICKERING
3.
CONTROL PANEL
SECURE LIGHTING
DOES NOT OPERATE
2.
Check fuse in prime mover
(refer to applicable prime
mover TM).
3.
Disconnect intervehicular
cable connections of
M969A3 and prime mover
and check for dirty or
corroded contacts in both
plugs.
Disconnect intervehicular cable
connections of M969A3 and
prime mover and check for dirty
or corroded contacts in both
plugs.
If fuse is blown, notify
Organizational maintenance. If
fuse is okay, go to step 3.
Clean plugs or receptacles and
reconnect to M969A3. If
semitrailer lights still do not
operate properly, notify
Organizational maintenance.
Clean plugs or receptacles and
reconnect to M969A3. If
semitrailer lights still do not
operate properly, notify
Organizational maintenance.
Notify Organizational
maintenance.
END OF TASK