TM 9-2330-330-14&P
0013 00-2
BRAKE SYSTEM TROUBLESHOOTING—Continued
0013 00
Table 1. Troubleshooting Procedures—Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2.
NO BRAKES OR BRAKES
ARE WEAK
1.
Apply prime mover service
brakes. Check position of
shut-off valves on prime
mover.
NOTE
Some prime movers may not
be equipped with shut-off
valves (refer to applicable
prime mover TM).
Open shut-off valves. If valves
are already open, go to step 2.
3.
BRAKE APPLICATION OR
RELEASE IS SLOW
4.
BRAKES GRAB
2.
Check airbrake system for
leaks or damage.
Set parking brake of prime
mover (refer to applicable prime
mover TM). Check to see if
airbrake system is leaking or
damaged.
Set parking brake of prime
mover (refer to applicable prime
mover TM). Check semitrailer air
reservoir for moisture.
If no damage or leaks are
detected, notify Organizational
maintenance that further
troubleshooting is required. If
damage is detected, notify
Organizational maintenance.
If no damage or leaks are
detected, notify Organizational
maintenance that further
troubleshooting is required. If
damage is detected, notify
Organizational maintenance.
Open air reservoir, drain valve,
and drain any accumulated
moisture from valve. If no
moisture is present, notify
Organizational maintenance that
further troubleshooting is
required.
END OF TASK