TM 9-2330-330-14&P
0014 00-3/4 blank
FUEL SYSTEM TROUBLESHOOTING
0014 00
Table 1. Troubleshooting Procedures—Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
3.
FUEL DOES NOT FLOW
DURING ANY NON-
FILTERED FUELING
OPERATION
1.
Check to see if emergency
valve A control handle is in
the open position.
If valve A is in closed position,
open it. Verify problem is solved.
If valve is already in open
position, go to step 2.
2.
Verify all valves are set per
fuel operations schematic.
3.
Check for debris or dirt in
nozzle screen of quick
coupling.
4.
Check pump inlet screen for
debris or dirt clogging inlet.
Set valves per schematic on tool
box lid (refer to WP 0007 00).
Verify problem is solved. If valves
are already set properly, go to
step 3.
If dirt or debris are present in
nozzle screen, clean screen per
WP 0041 00. Verify problem is
solved. If dirt and debris are not
present, go to step 4.
Clean inlet screen per WP 0041
00. Verify problem is solved. If
screen was clean, notify
Organizational maintenance that
further troubleshooting is
required.
END OF TASK