TM-9-2330-330-14-P

SEMITRAILER, FUEL TANKER: 5000-GALLON, FUEL-DISPENSING, AUTOMOTIVE, M969A3

TECHNICAL MANUAL; OPERATOR’S, ORGANIZATIONAL, DIRECT SUPPORT, AND GENERAL SUPPORT MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST)

NOVEMBER 2005

  TM-9-2330-330-14-P - Page 135 of 1116

TM 9-2330-330-14&P
0019 00-1
LIGHT SYSTEMS TROUBLESHOOTING
0019 00
THIS WP COVERS:
Light Systems Troubleshooting
INITIAL SETUP:
Maintenance Level
Tools and Special Tools
Organizational
Tool kit, general mechanic’s (item 4, WP 0171 00)
Multimeter (item 2, WP 0171 00)
References
Applicable prime mover TM
WP 0046 00
WP 0054 00
WP 0057 00
WP 0058 00
WP 0061 00
WP 0065 00
To troubleshoot the M969A3 light systems, perform the test/inspections and corrective actions provided in
Table 1.
Table 1. Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
ALL SEMITRAILER
LIGHTS ARE
INOPERABLE/DIM OR
FLICKERING
2.
ONE OR MORE LIGHTS
WILL NOT OPERATE
At front access hatch cover,
check for loose/dirty or corroded
receptacle ground leads and
terminal strip leads (refer to WP
0058 00).
NOTE
Refer to WP 0046 00 for
routing of electrical wires and
electrical schematic.
1.
At front access hatch
cover, check for
loose/dirty or corroded
receptacle ground leads
and terminal strip leads
(refer to WP 0058 00).
Clean/tighten receptacle ground
or terminal strip leads. Verify
problem is solved.
Clean/tighten receptacle ground
or terminal strip leads. Verify
problem is solved. If loose/dirty
or corroded leads are not
present, go to step 2.


Back to Top