TM-9-2330-330-14-P

SEMITRAILER, FUEL TANKER: 5000-GALLON, FUEL-DISPENSING, AUTOMOTIVE, M969A3

TECHNICAL MANUAL; OPERATOR’S, ORGANIZATIONAL, DIRECT SUPPORT, AND GENERAL SUPPORT MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST)

NOVEMBER 2005

  TM-9-2330-330-14-P - Page 143 of 1116

TM 9-2330-330-14&P
0023 00-1
ENGINE TROUBLESHOOTING
0023 00
THIS WP COVERS:
Engine Troubleshooting
INITIAL SETUP:
Maintenance Level
Tools and Special Tools
Organizational
Tool kit, general mechanic’s (item 4, WP 0171 00)
Personnel Required
References
Two
WP 0039 00
WP 0108 00
WP 0113 00
WP 0044 00
WP 0109 00
WP 0119 00
WP 0056 00
WP 0112 00
WP 0120 00
WP 0065 00
WP 0114 00
WP 0151 00
WP 0103 00
WP 0118 00
WP 0152 00
WP 0107 00
To troubleshoot the engine, perform the test/inspections and corrective actions provided in Table 1.
Table 1. Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
ENGINE STARTER WILL
NOT RUN
1.
Check each battery for
output (12–14 V dc).
If battery voltage is less than 12–
14 V dc, replace battery (refer to
WP 0056 00). Verify problem is
solved. If voltage is correct, go to
step 2.
2.
Inspect battery cables for
broken or frayed cables
and loose or corroded
terminals.
3.
Turn engine run switch ON
and check engine start
switch at both terminals for
24–28 V dc when engine
start switch is placed in
START position.
If cables are broken or frayed,
repair/replace cables (refer to
WP 0056 00) and clean
terminals. Verify problem is
solved. If cables are okay, go to
step 3.
If 24–28 V dc are present at both
terminals, go to step 4. If 24–28
V dc is not present, replace
engine start switch (refer to WP
0120 00). Verify problem is
solved.


Back to Top