TM-9-2330-330-14-P

SEMITRAILER, FUEL TANKER: 5000-GALLON, FUEL-DISPENSING, AUTOMOTIVE, M969A3

TECHNICAL MANUAL; OPERATOR’S, ORGANIZATIONAL, DIRECT SUPPORT, AND GENERAL SUPPORT MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST)

NOVEMBER 2005

  TM-9-2330-330-14-P - Page 149 of 1116

TM 9-2330-330-14&P
0023 00-7
ENGINE TROUBLESHOOTING—Continued
0023 00
Table 1. Troubleshooting Procedures—Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
9.
ENGINE EXHAUST IS
BLACK OR FUEL
CONSUMPTION IS
EXCESSIVE—Continued
10.
PREHEAT INDICATOR
LAMP WILL NOT LIGHT
1.
Check for restricted air
passages or red band in
air restriction indicator.
2.
Check for dirty,
contaminated, or wrong
grade of fuel.
3.
Check tachometer to see if
engine is operating at
proper rpm.
1.
Listen for clicking noise at
engine control box when
preheat indicator lamp
switch is moved to ON
position.
2.
Check for continuity at
preheat switch.
If air passages are restricted,
clear restricted passages (refer
to WP 0113 00) and/or replace
air filter element (refer to WP
0039 00). Verify problem is
solved. If air passages were
clear, go to step 2.
If fuel is dirty, drain and remove
fuel tank (refer to WP 0108 00)
and fuel lines and replace and
refill tank with clean fuel.
Replace fuel filter (refer to WP
0109 00). Verify problem is
solved. If fuel was okay, go to
step 3.
If engine is not operating at
proper rpm, adjust throttle cable
(refer to WP 0114 00). Verify
problem is solved. If engine is
operating at proper rpm, notify
Direct Support maintenance that
further troubleshooting is
required.
If clicking noise is heard, replace
indicator lamp (refer to WP 0120
00). Verify problem is solved. If
noise is not heard, go to step 2.
If continuity is not present in
switch, replace switch (refer to
WP 0120 00). Verify problem is
solved. If continuity is present, go
to step 3.


Back to Top