TM-9-2330-330-14-P

SEMITRAILER, FUEL TANKER: 5000-GALLON, FUEL-DISPENSING, AUTOMOTIVE, M969A3

TECHNICAL MANUAL; OPERATOR’S, ORGANIZATIONAL, DIRECT SUPPORT, AND GENERAL SUPPORT MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST)

NOVEMBER 2005

  TM-9-2330-330-14-P - Page 153 of 1116

TM 9-2330-330-14&P
0025 00-1/2 blank
BATTERY TROUBLESHOOTING
0025 00
THIS WP COVERS:
Battery Troubleshooting
INITIAL SETUP:
Maintenance Level
Tools and Special Tools
Organizational
Tool kit, general mechanic’s (item 4, WP 0171 00)
Multimeter (item 2, WP 0171 00)
References
TM 9-6140-200-14
WP 0056 00
To troubleshoot the batteries, perform the test/inspections and corrective actions provided in Table 1.
Table 1. Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
BATTERY IS LOW OR
DISCHARGED
NOTE
Batteries should be removed
from M969A3 prior to
servicing, checking, and
charging. All battery servicing,
testing, and charging shall be
in accordance with
TM 9-6140-200-14.
1.
Check for excess moisture
or dirt on top of batteries.
2.
Perform specific gravity
test on battery (refer to
TM 9-6140-200-14).
NOTE
Verify battery is fully charged
prior to performing load test.
3.
Perform load test on
battery (refer to
TM 9-6140-200-14).
Clean battery top. If electrolyte is
low, replenish electrolyte. Go to
step 2.
If battery passes specific gravity
test, go to step 3.
If battery passed load test,
battery is serviceable and may
be reinstalled in M969A3. If
battery fails, replace battery
(refer to
WP 0056 00).
END OF TASK


Back to Top