TM 9-2330-330-14&P
0028 00-1/2 blank
PIPING CONTROL COMPONENTS TROUBLESHOOTING
0028 00
THIS WP COVERS:
Piping Control Components Troubleshooting
INITIAL SETUP:
Maintenance Level
References
Organizational
WP 0007 00
WP 0130 00
To troubleshoot the M969A3 piping control components, perform the test/inspections and corrective
actions provided in Table 1.
Table 1. Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
WITH EMERGENCY VALVE A
HANDLE IN CLOSED
POSITION, FUEL CONTINUES
TO FLOW OUT OF TANK
1.
Verify all valves are set per
fuel operations schematic
on tool box lid (refer to WP
0007 00).
Set valves per schematic on tool
box lid (refer to WP 0007 00). If
valves are set properly, go to
step 2.
2.
Move handle and observe
valve A lever movement at
valve A under tank (refer to
WP 0130 00).
If lever movement is observed
and fuel flow stops, verify
problem is solved. If fuel
continues to flow, notify Direct
Support maintenance.
END OF TASK