TM-9-2330-330-14-P

SEMITRAILER, FUEL TANKER: 5000-GALLON, FUEL-DISPENSING, AUTOMOTIVE, M969A3

TECHNICAL MANUAL; OPERATOR’S, ORGANIZATIONAL, DIRECT SUPPORT, AND GENERAL SUPPORT MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST)

NOVEMBER 2005

  TM-9-2330-330-14-P - Page 364 of 1116

TM 9-2330-330-14&P
0071 00-4
AIR BRAKE CHAMBERS MAINTENANCE—Continued 0071
00
2.
With prime mover connected (refer to WP 0007 00) and semitrailer brakes applied, coat flanges
(12) and connections (13) on air brake chamber (8) with soapy water.
3.
Inspect flanges (12) and connections (13) for leakage, indicated by bubbles.
4.
If leakage is found at flange (12), replace chamber (8).
5.
If leakage is found at connections (13), tighten fittings.
FOLLOW-ON TASKS
1.
Uncage fail-safe brake chambers (WP 0078 00).
2.
Disconnect semitrailer grounding cables (WP 0007 00).
END OF TASK