0036-3/(4 blank)
TM 9-2330-335-14&P
0036
INSTALLATION - CONTINUED
CAUTION
Sensor cables must be strapped at the 12 o’clock or 3 o’clock position on the axle (top or rearward
side of axle) to protect them during off-road operation. Use as many tiedown straps as required to
ensure the cables are tightly secured to the axle ends. Failure to do so could result in damage
to equipment.
NOTE
Attach nylon tiedown straps to axle allowing for easy replacement. Locking tab shall be situated
within 90 degrees of axle top.
7.
Secure sensor cables (Figure 2, Item 8) to axle with nylon tiedown straps (Figure 2, Item 11).
Figure 2.
Sensor Cables.
036
END OF TASK
FOLLOW-ON TASKS
00036
1.
Connect semitrailer to prime mover.
2.
Raise landing legs.
3.
Remove/store chocks and ground boards.
4.
Road test to check for ABS warning light operation.
END OF TASK
END OF WORK PACKAGE
447-0066