TM 9-2330-356-14
B-Before
3-24
Table 3-1. Operator/Crew Preventive Maintenance Checks and Services (Con‘t).
D-During
A-After
W-Weekly
M-Monthly
ITEM TO BE INSPECTED
PROCEDURE Check for and have repaired,
filled or adjusted as needed.
Tank.
a. Inspect tank shell for dents and leaks.
b. Check for leaks around fusible vent caps.
Tighten caps if loose.
c. Check for leaks around manhole cover. If
leaks are evident, check for damaged cover
gasket, loose mounting ring, and that cover is
securely latched.
Catwalk Drains.
Inspect for clogged drains. Remove foreign matter.
Emergency Valve and Vent.
Esure that all valves are closed. Operate control
ever A and ensure that the cable is actuating the
emergency valve lever and opens the vent on top of
semitrailer.
Emergency Valve Shut-off.
Ensure that all valves are closed. Move control
ever A to the OPEN position. On the front curbside
of the semitrailer, pull the emergency valve shut-off
control. Observe that control lever A has moved to
he CLOSED position.
Cabinet Door Shut-off (M970 and M970A1).
Ensure that all valves are closed. Open the hose
reel cabinet door. Move control lever A to the OPEN
position. Close the cabinet door and observe that
control lever A moves to the CLOSED position.
Brake System.
a. With towing vehicle coupled to semitrailer,
apply semitrailer brakes and inspect all air lines
and fittings for leaks.
b. Apply semitrailer brakes and observe
operation.
c. Drain water from both air reservoirs by
opening the air reservoir drain cocks.
Equipment Is Not
Ready/Available If:
Tank shell has leaks.
Leaks are evident.
Manhole cover gasket
aged.
Control lever A will not
is dam-
actuate
emergency valve lever, or vent
fails to open.
Control lever A does not move
to the CLOSED position.
Control lever A does not move
to the CLOSED position.
Brakes do not stop semitrailer,
or semitrailer pulls to one side.