TM-9-2330-356-14

SEMITRAILER, TANK: 5000 GALLON, BULK HAUL, SELF LOAD/UNLOAD M967 AND M967A1; SEMITRAILER, TANK: 5000 GALLON, FUEL DISPENSING, AUTOMOTIVE M969 AND M969A1; SEMITRAILER, TANK: 5000 GALLON, FUEL DISPENSING, UNDER/OVERWING AIRCRAFT M970 AND M970A1

TECHNICAL MANUAL; OPERATOR’S, UNIT, DIRECT SUPPORT, AND GENERAL SUPPORT MAINTENANCE MANUAL

OCTOBER 1990

  TM-9-2330-356-14 - Page 123 of 528

TM 9-2330-356-14
Table 3-1. Operator/Crew Preventive Maintenance Checks and Services (Con‘t).
B-Before
D-During
A-After
W-Weekly
M-Monthly
ITEM
INTERVAL
ITEM TO BE INSPECTED
PROCEDURE: Check for and have repaired,
Equipment Is Not
NO.
B
D
A
W
M
filled or adjusted as needed.
Ready/Available If:
25
Deadman Control (M970 and M970A1).
a. Unwind deadman control hoses and check
Hose will not unwind or binding
for operation of hose reel.
is noticed in the hose reel when
unwinding or rewinding hose.
b. Inspect for damage to the control and hoses.
Leaks are evident at connec-
Check for leaks when operating the control.
tions.
26
Deadman Gage.
a. Check deadman gage for damage (fig. 2-15).
b. Check at what pressure the 3-inch control
valve opens. Pressure gage should read 80 psi.
27
Nozzles.
Clean screens.
28
Grounding Devices.
a. Check static reel operation. Inspect for
Missing or loose hardware.
missing grounding clips and loose or missing
mounting hardware.
b. Check portable grounding rod to ensure that it
Missing from vehicle or dam-
is not damaged or missing.
aged.
3-27