TM 9-2330-356-14
3-10. Hose Reels
a.
Hose Reef Hoses.
After a hose reel hose is
unreeled from the hose reel for a fuel servicing operation,
visually check the hose for damage. If damage is noticed,
notify unit maintenance.
b.
Lubrication.
Lubricate the hose reel side bearings
and the hose reel handcrank operation shafts weekly
(Section I, Chapter 3).
3-11. Tool Box
a.
Cleaning.
Periodically clean tool box of dirt and
debris. Make sure drain holes are open.
b.
Inspect.
Inspect tool box cover and tool box for
damage. Report any damage to unit maintenance.
3-12. Filter/Separator Sump
Drain water from filter/separator after each period of
operation (para 2-13
d).
3-13. Reassembling Breakaway Fitting (M970 and
M970A1)
NOTE
Installation of shear pins may be done with-
out removing connector from vehicle.
a.
Retract sleeve
segments (fig. 3-24).
and remove broken shear pin
Figure 3-24. Removing Broken Shear Pins in
Breakaway Fitting.
b.
Remove three new shear pins from compartment
under external O-ring (fig. 3-25).
c.
Retract sleeve, push connector halves together
and hold. Insert pins in three holes until flush (pins must
engage race in mating half). Sleeve will then slide forward
and cover pins.
Figure 3-25. Installing New Shear Pins in
Breakaway Fitting.
3-14. Vehicle Nozzle (M969 and M969A1)
a. Service.
The screen in the nozzle (fig. 3-26) must
be cleaned periodically and whenever flow is restricted
through nozzle.
(1) Unscrew spout (fig. 3-26) from nozzle.
(2) Remove screen from within the spout.
WARNING
Dry cleaning solvent P-D-680 is toxic and
flammable.
Always wear protective
goggles and gloves, and use only in a well-
ventilated area. Avoid contact with skin,
eyes, and clothes, and DO NOT breathe va-
pors. DO NOT use near open flame or ex-
cessive heat. The solvent’s flash point is
100°F-138°F (38°C-59°C). If you be-
come dizzy while using cleaning solvent,
Immediately get fresh air and medical help.
If solvent contacts eyes, Immediately wash
your eyes with water and get medical aid.
Compressed air used for drying or clean-
ing purposes must not exceed 30 psi
(207 kPa).
Wear protective clothing
3-36