TM-9-2330-356-14

SEMITRAILER, TANK: 5000 GALLON, BULK HAUL, SELF LOAD/UNLOAD M967 AND M967A1; SEMITRAILER, TANK: 5000 GALLON, FUEL DISPENSING, AUTOMOTIVE M969 AND M969A1; SEMITRAILER, TANK: 5000 GALLON, FUEL DISPENSING, UNDER/OVERWING AIRCRAFT M970 AND M970A1

TECHNICAL MANUAL; OPERATOR’S, UNIT, DIRECT SUPPORT, AND GENERAL SUPPORT MAINTENANCE MANUAL

OCTOBER 1990

  TM-9-2330-356-14 - Page 136 of 528

TM 9-2330-356-14
Figure 3-32. Engine Air Cleaner Restriction Indicator.
b.
To service the filter, loosen clamp (fig. 3-33) and
remove end cap.
CAUTION
Never run engine with filter or dust collector
removed. Damage to engine could result.
c.
Unscrew the wingnut and washer and remove the
element.
d.
Remove baffle from end cap and remove any
accumulated dirt.
e.
Use a clean rag to wipe clean the interior of air
cleaner and end cap.
WARNING
Compressed air used for drying or cleaning
purposes must not exceed 30 psi (207 kpa).
Wear protective clothing (goggles and
gloves) and use caution to avoid injury to
personnel.
f.
Remove the rain cap and clean with compressed
air.
g.
Replace baffle in end cap.
h.
Clean filter element. After six cleanings or
annually, have unit maintenance obtain a replacement
filter element.
i.
Install new or cleaned filter element in air
cleaner body. Fasten in place with washer and wingnut.
j .
Replace filter end cap. Ensure that the portion of
the end cap marked TOP is at the top. Secure end cap by
tightening clamp.
Figure 3-33. Exploded View of Air Cleaner.
3-40


Back to Top