TM 9-2350-238-20-1
2-12. ELECTRICAL CIRCUIT TROUBLESHOOTING (CONT).
K. BATTERY-GENERATOR INDICATOR CIRCUIT.
Step 1.
To access indicators, remove driver's instrument (gage) panel. Refer to
page 2-571. Disconnect lead 27 from BATTERY-GENERATOR indicator.
Place red probe in lead 27. Ground black probe. Set MASTER and INST
switches ON. If multimeter indicates no voltage, connect lead 27 to
BATTERY-GENERATOR indicator and go to step 2. If multimeter
indicates about 24 volts, go to step 3. Set MASTER and INST switches
OFF.
2-148