2-64. MAINTENANCE OF WATER BY-PASS AND CROSSOVER TUBES (CONT).
1
Inspect for broken, damaged, or missing parts.
2
Repair is by replacement of authorized parts (TM 9-2815-202-24P).
1
Slide two nonmetallic hoses (1) and four hose clamps (2) onto ends of water by-pass tube (3).
2
Install water by-pass tube (3) between water pump (4) and thermostat cover (5). Slide
nonmetallic hoses (1) onto water pump and thermostat cover and secure with hose
3
Install machine bolt (6), flat washer (7), new Iockwasher (8), and hexagon plain nut
loop clamp (10) to angle bracket (11).
clamps (2).
(9) securing
4
Slide two nonmetallic hoses (12) and four hose clamps (13) onto ends of water crossover tube
(14).
5
Install water crossover tube (14) between engine water outlet (15) and flange to tube elbow (16)
and secure with hose clamps (13).
6
Install pipe plug (17) and pipe plug (18).
2-538