WARNING
TM 9-2350-238-20- 2
2-91 .
MAINTENANCE OF GAS PARTICULATE FILTER UNIT, AIR PURIFIER ASSEMBLY ,
HOUSING PRECLEANER ASSEMBLY, AND GROUND CABLE ASSEMBLY (CONT) .
1
2
3
4
5
• Make sure MASTER switch is
OFF before repairing electrica l
components. Failure to observ e
this warning could result in in-
jury or death .
• Failure to remove or disconnec t
the batteries before removing o r
installing any electrical wirin g
harness or lead may result in in-
jury or damaged equipment .
Set MASTER switch to OFF. Loose n
machine screw (1) and disconnect groun d
cable assembly (2) from gas particulat e
filter unit (3) .
Unscrew and disconnect connector (4 )
from gas particulate filter unit (3) .
Disconnect M7 hose assembly (5) an d
M10 hose assembly (6) from gas par-
ticulate filter unit (3) .
Release holddown latch (7). Remove gas
particulate filter unit (3) from fram e
assembly (8). Remove two shock moun t
to boom cylinders hose clamps (9 an d
10) .
Remove four assembled washer bolts (11 )
securing frame assembly (8) and groun d
cable assembly (2) to shock assembly
mount (12) .
2-31 0