TM-9-2350-256-10

RECOVERY VEHICLE, FULL TRACKED: MEDIUM, M88A1

OPERATOR'S MANUAL

OCTOBER 2014

  TM-9-2350-256-10 - Page 191 of 796

MANUAL PURGE PERSONNEL HEATER
1.
Move START/OFF/RUN switch (Figure 3, Item 4) to OFF position.
2.
Move START/OFF/RUN switch (Figure 3, Item 4) on heater control box (Figure 3, Item 3) momentarily to
START position for at least 10 seconds, then to OFF position. This will allow heater (Figure 3, Item 2) to
purge. This will take approximately 4 minutes.
Figure 3.
Heater and Heater Control Box.
END OF TASK
END OF WORK PACKAGE
TM 9-2350-256-10
0037
0037-7/blank