Table 1.
Operator Preventive Maintenance Checks and Services (PMCS) – Weekly - Continued.
ITEM
NO.
INTERVAL
ITEM TO BE
CHECKED OR
SERVICED
PROCEDURE
EQUIPMENT
NOT READY/
AVAILABLE IF:
1. Check air restriction gauge (WP 0119) and if
necessary, perform Step 2.
2. Remove dust cover and clean dust and debris from
the cover, filter housing, and filter element (WP 0119).
Any holes or tears in the
air filter element, dust
cover seal, or air
induction tubes. Any
missing hose or hose
clamps. Air cleaner
unserviceable.
3. Check for damaged or unserviceable components of
air cleaner system.
17
WEEKLY
Mechanical
Transmission
1. Open floor access plate #9 (WP 0027).
NOTE
If oil level is on F mark, proceed to Step 4.
2. Remove oil gauge rod to verify oil level is to the F
mark on gauge rod.
3. Add proper grade oil if level is not to F mark
(WP 0101).
4. Insert oil gauge rod.
5. Check area of mechanical transmission for any
leaks.
Any Class III oil leaks.
6. Check Power Takeoff (PTO) shaft boot for proper
installation and tears.
7. Close floor access plate #9 (WP 0027).
Figure 13.
Mechanical Transmission Breather Cap and Oil Gauge Rod.
TM 9-2350-256-10
0099
0099-15