TM-9-2350-260-20-1-3

TANK, COMBAT, FULL TRACKED 105-MM GUN, M60 2350-00-678-5773 (HULL)

TECHNICAL MANUAL; ORGANIZATIONAL MAINTENANCE VOLUME 3 OF 4 CHAPTERS 10 THRU 15

  TM-9-2350-260-20-1-3 - Page 67 of 783

TM 9-2350-260-20-1-3
MASTER CONTROL PANEL ASSEMBLY REPLACEMENT (Sheet 3 of 5)
6.
Disconnect connectors (H)(CKT 15).
7.
Disconnect circuit no. 19 connector (J) from switch (K).
8.
Using spanner wrench, disconnect main light switch connector (L) from switch (M).
9.
Disconnect circuit no. 415C connector (N) from switch (P).
10. Disconnect circuit no. 415 connector (Q) from indicator light (R).
NOTE
Some early model M60 tanks may have an additional circuit (CKT 25) coming from
the master control panel.
Remove control panel slowly and look for this circuit.
If
circuit (CKT 25) is present, disconnect connector and go to step 11.
11. Remove master control panel (A) from tank.
Go on to Sheet 4
10-55


Back to Top