TM-9-2350-261-20-1

CARRIER, M113A2, M577A2, M1064, M1068, M1059 AND M901A1

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL - VOLUME 1 OF 4

  TM-9-2350-261-20-1 - Page 122 of 346

TM 9-2350-261-20-1
ENGINE DOES NOT CRANK
0009 00
INITIAL SETUP:
Maintenance Level
Unit
Tools and Special Tools
Digital Multimeter (WP 0780 00, Item 43)
General Mechanic’s Tool Kit (WP 0780 00, Item 29)
Socket Wrench Set (WP 0780 00, Item 96)
Personnel Required
Unit Mechanic
Helper (H)
References
See your -10
Equipment Condition
Engine stopped/shutdown (see your -10)
Carrier blocked (see your -10)
Trim vane lowered (see your -10)
Power plant access door open (see your -10)
Driver’s power plant access panel removed (see your
-10)
T
1.
Turn MASTER SWITCH to ON (see your -10).
2.
Remove cover (1) from auxiliary power receptacle (2).
3.
Measure voltage between positive (+) terminal (3) and
negative (-) terminal (4).
4.
Does multimeter read more 17 volts?
TN
1.
Clean, inspect, and repair carrier
batteries (WP 0302 00 and
WP 0303 00).
2.
Verify no faults found.
000900-1