TM-9-2350-261-20-1

CARRIER, M113A2, M577A2, M1064, M1068, M1059 AND M901A1

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL - VOLUME 1 OF 4

  TM-9-2350-261-20-1 - Page 262 of 346

TM 9-2350-261-20-1
INFRARED PERISCOPE WORKS IMPROPERLY — Continued
0040 00
BY
1.
Remove periscope power pack 517 lead (1) from I.R.
power pack (2).
2.
Measure resistance between lead ends (1) and (3)
(inner and outer).
3.
Does multimeter read 0 ohms both times?
BYN
1.
Replace I.R. periscope power
pack lead.
2.
Install original I.R. power pack
(WP029100orWP029300)
.
3.
Verify no faults found.
B2Y
1.
Remove circuit plug 516 (1) and 516 A (2) from I.R.
POWER switch jacks (3) and (4).
2.
Measure resistance between I.R. POWER switch jacks
(3) and (4) with switch ON.
3.
Does multimeter read 0 ohms?
B2YN
1.
Replace I.R. POWER switch
(WP 0241 00).
2.
Install original I.R. power pack
(WP029100orWP029300)
.
3.
Verify no faults found.
004000-3


Back to Top