TM 9-2350-261-20-1
INFRARED PERISCOPE WORKS IMPROPERLY — Continued
0040 00
B3Y
1.
Remove instrument panel cable assembly circuit 27 plug (1)
from instrument panel circuit breaker (2).
2.
Measure resistance between circuit 516 plug (3) and
circuit27plug(1)
.
3.
Does multimeter read 0 ohms?
B3YN
1.
Repair instrument panel cable
assembly circuit 516 (WP 0312 00).
2.
Install original I.R. power pack
(WP029100orWP029300)
.
3.
Verify no faults found.
B4Y
1.
Remove cable assembly circuit 516A plug (1) from
I.R. power pack (2).
2.
Turn MASTER SWITCH to ON (see your -10).
3. TurnI
.R
.POWERswitchtoON(seeyour-10)
.
4.
Measure voltage between cable assembly circuit 516A
plug (1) and ground.
5.
Turn MASTER SWITCH to OFF (see your -10).
6.
Did multimeter read less than 17 volts?
B4YN
1.
Repair front main harness circuit
516A (WP 0312 00).
2.
Install original I.R. power pack
(WP029100orWP029300)
.
3.
Verify no faults found.
004000-4