TM 9-2350-261-20-1
BATTERY/GENERATOR INDICATOR MALFUNCTIONS
0049 00
INITIAL SETUP:
Maintenance Level
Unit
Tools and Special Tools
Digital Multimeter (WP 0780 00, Item 43)
General Mechanic’s Tool Kit (WP 0780 00, Item 29)
Personnel Required
Unit Mechanic
References
WP 0238 00
Equipment Condition
Engine stopped/shutdown (see your -10)
Carrier blocked (see your -10)
T
1.
Remove instrument panel for access (WP 0238 00).
2.
Remove circuit 27E plug (1) from battery generator
indicator jack (2).
3.
Remove circuit 10 plug (3) from instrument panel
circuit breaker jack (4).
4.
Measure resistance between circuit 27E plug (1) and
circuit10plug(3)
.
5.
Does multimeter read 0 ohms?
TN
1.
Repair master power harness circuit
27E (WP 0312 00).
2.
Verify no faults found.
Y
1.
Replace BATTERY/GENERATOR indicator (WP 0240 00).
2.
Verify no faults found.
00 4
9 00-1/2 blank