TM 9-2350-261-20-2
REPLACE AUXILIARY TANK AND PARTS — Continued
0206 00
INSTALLATION
WARNING
Adhesive, primer, sealant compounds, and isopropyl alcohol are toxic and flammable. These
compounds are toxic to eyes, skin, and respiratory tract. Continued exposure can make you
dizzy and irritate your eyes and throat.
Always use in well ventilated areas, away from heat, sparks, and flames. Do not breathe fumes.
Do not allow into contact with skin and eyes. Use goggles or face shield and protective gloves.
1.
Apply thin coat of sealing compound (WP 0782 00, Item 62) to both sides of new gasket (1).
2.
Install new gasket (1), filler neck (2), and bracket (3) on auxiliary tank (4). Secure with four screws (5), flat washers (6),
and new lockwashers (7).
3.
Secure chain (8) to bracket (3) and filler cap (9) with two hooks (10).
4.
Install filler cap (9) in filler neck (2).
020600-3