TM 9-2350-261-20-2
REPLACE AUXILIARY TANK TO COOLANT PUMP TUBE — Continued
0207 00
INSTALLATION
WARNING
Adhesive, primer, sealant compounds, and isopropyl alcohol are toxic and flammable. These
compounds are toxic to eyes, skin, and respiratory tract. Continued exposure can make you
dizzy and irritate your eyes and throat.
Always use in well ventilated areas, away from heat, sparks, and flames. Do not breathe fumes.
Do not allow into contact with skin and eyes. Use goggles or face shield and protective gloves.
1.
Apply a light, even coat of sealing compound to external threads of adapter (7).
2.
Install adapter (7) in oil cooler elbow (12).
3.
Install clamp (3) on tube (8).
4.
Secure hose (10) to auxiliary tank (11) and to tube (8) with two clamps (9).
5.
Secure hose (6) to tube (8) and adapter (7) with two clamps (5).
6.
Secure clamp (3) to bracket (4) with screw (1) and washer (2).
0207 00-2