TM 9-2350-261-20-2
REPLACE AUXILIARY TANK TO COOLANT PUMP TUBE
0207 00
THIS WORK PACKAGE COVERS:
Removal (page 0207 00-1).
Installation (page 0207 00-2).
INITIAL SETUP:
Maintenance Level
Unit
Tools and Special Tools
General Mechanic’s Tool Kit (WP 0780 00, Item 29)
Materials/Parts
Sealing compound (WP 0782 00, Item 60)
Personnel Required
Unit Mechanic
Equipment Condition
Engine stopped/shutdown (see your -10)
Carrier blocked (see your -10)
Trim vane lowered and power plant front access door
open (see your -10)
Drain cooling system (WP 0193 00)
REMOVAL
1.
Remove screw (1), washer (2), and clamp (3) from bracket (4).
2.
Loosen two clamps (5). Disconnect hose (6) from adapter (7) and tube (8).
3.
Loosen two clamps (9). Disconnect hose (10) from tube (8) and auxiliary tank (11).
4.
Remove adapter (7) from oil cooler elbow (12).
5.
Remove tube (8) from carrier, and clamp (3) from tube.
020700-1