REPLACE RAMP CONTROL VALVE TO HYDRAULIC TANK HOSE — Continued
0583 00
INSTALLATION
1.
Install quick disconnect assembly (7) on adapter (8).
WARNING
Adhesive, primer, sealant compounds, and isopropyl alcohol are toxic and flammable. These
compounds are toxic to eyes, skin, and respiratory tract. Continued exposure can make you
dizzy and irritate your eyes and throat.
Always use in well ventilated areas, away from heat, sparks, and flames. Do not breathe fumes.
Do not allow into contact with skin and eyes. Use goggles or face shield and protective gloves.
2.
Apply sealing compound to male threads of hose (5). Install hose on quick disconnect assembly (7) and elbow (6).
3.
Place two clamps (3) on hose (5). Align clamps with oil filter bracket screws (4). Secure with two washers (2) and
new locknuts (1).