TM 9-2350-261-20-4
REPLACE POWER CONTROL ENCLOSURE ASSEMBLY A1 (M1068 ONLY)
0731 00
THIS WORK PACKAGE COVERS:
Removal (page 0731 00-1).
Installation (page 0731 00-2).
INITIAL SETUP:
Maintenance Level
Unit
Tools and Special Tools
General Mechanic’s Tool Kit (WP 0780 00, Item 29)
Materials/Parts
Lockwasher (2)
Personnel Required
Power-Generation Equipment Repairer 52D10
Helper (H)
Equipment Condition
Engine stopped (see your -10)
Carrier blocked (see your -10)
All external power disconnected (TM 11-7010-256-
12&P)
Battery ground lead disconnected (WP 0294 00)
Roadside data panel A13 removed (WP 0727 00)
Cascade remote harness W15 removed (WP 0745 00)
REMOVAL
1.
Remove two screws (1), lockwashers (2), and bracket (3) from power control enclosure (4). Discard lockwashers.
NOTE
Tag all cables/connectors before removal for proper installation later.
2.
Disconnect all cables/connectors (5) from left and right sides of power control enclosure (4).
3.
Remove eight screws (6), washers (7), and power control enclosure (4) from inverter housing (8). Have helper assist.
073100-1