TM-9-2350-261-20-4

CARRIER, M113A2, M577A2, M1064, M1068, M1059 AND M901A1

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL - VOLUME 4 OF 4

  TM-9-2350-261-20-4 - Page 440 of 767

TM 9-2350-261-20-4
REPLACEACPOWEREXTENSIONBOXA6ANDDCPOWER
EXTENSION BOX A9 AND MOUNT (M1068 ONLY)
0735 00
THIS WORK PACKAGE COVERS:
Removal (page 0735 00-1).
Installation (page 0735 00-2).
INITIAL SETUP:
Maintenance Level
Unit
Tools and Special Tools
General Mechanic’s Tool Kit (WP 0780 00, Item 29)
Materials/Parts
Locknut (8)
Personnel Required
Power-Generation Equipment Repairer 52D10
Equipment Condition
Engine stopped (see your -10)
Carrier blocked (see your -10)
All external power disconnected (TM 11-7010-256-
12&P)
Battery ground lead disconnected (WP 0294 00)
REMOVAL
1.
Disconnect UPS cable W42 (1) from connector (2) on DC power extension box (3).
2.
Disconnect UPS cable W43 (4) from connector (5) on AC power extension box (6).
3.
Disconnect cable W10 (7) from connector (8) on DC power extension box (3).
4.
Disconnect cable W45 (9) from connector (10) on DC power extension box (3).
5.
Disconnect cable W7 (11) from connector (12) on AC power extension box (6).
6.
Remove eight locknuts (13), screws (14), and two power extension boxes (3) and (6) from mount (15). Discard locknuts.
7.
Remove four screws (16), washer (17), and mount (15) from work station (18).
073500-1