TM-9-2350-261-34

CARRIER, M113A2, M577A2, M1064, M1068, M1059 AND M901A1

TECHNICAL MANUAL; DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE MANUAL

  TM-9-2350-261-34 - Page 106 of 785

TM 9-2350-261-34
NO DC OUTPUT FROM DC POWER SUPPLY (M1068 ONLY) — Continued
0012 00
4Y
1.
Remove all power from SICPS system (see your -10
and TM 11-7010-256-12&P).
2.
Install all circuits on power supplies PS1 (1) and PS2 (2).
3.
Measure resistance between PS1 (+) OUTPUT terminal (3) and
DC bus bar at terminal 1 (4) of circuit breaker CB15 (5).
4.
Does multimeter read 0 ohms?
4YN
1.
Replace lead 31E (WP 0086 00
and see your -10).
2.
Verify no faults found.
001200-5