TM 9-2350-261-34
REPLACE ENGINE — Continued
0021 00
4.
Disconnect power plant wiring harness circuit 406 lead (5) from air box heater wiring harness connector (6).
5.
Remove screw (7), lockwasher (8), and three ground leads (9) from air box heater bracket (10). Discard lockwasher.
6.
Disconnect power plant wiring harness circuit 33 lead (11) from coolant temperature sending unit (12).
002100-3