TM 9-2350-261-34
REPLACE POWER PLANT WIRING HARNESS — Continued
0031 00
2.
Disconnect circuit 34 lead (1) from engine low oil pressure switch (2).
3.
Remove nut (3), two lockwashers (4), and circuit 6 lead (5) from starter solenoid (6). Discard lockwashers.
4.
Remove nut (7), two lockwashers (8), and circuit 74A lead (9) from solenoid (6). Discard lockwashers.
5.
Disconnect circuit 327 lead (10) from engine high oil temperature switch (11).
6.
Disconnect circuit 33 lead (12) from engine coolant temperature switch (13).
0031 00-2