TM-9-2350-261-34

CARRIER, M113A2, M577A2, M1064, M1068, M1059 AND M901A1

TECHNICAL MANUAL; DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE MANUAL

  TM-9-2350-261-34 - Page 569 of 785

TM 9-2350-261-34
INSTALL CAPSTAN KIT (M113A2 AND M1059 ONLY) — Continued
0072 00
8.
Make sure retainer (5) is installed in drum (6) with pin (7).
9.
Install drum (6) on adapter (3). Secure with retainer (5).
10. Measure and mark the correct positions for the smaller stowage support (1) and for the larger support (2) on top of carrier.
NOTE
All weld sizes are minimum. Do not exceed 1/16 inch (2 mm) over specified sizes.
11. Remove all paint, alodine, and debris from surfaces under stowage supports to be welded.
12. Weld stowage supports (1) and (2) to top plate of carrier as marked in Step 10 in accordance with TC 9-237. Use
electrode type 5356.
0072 00-4


Back to Top