TM-9-2350-273-BD

M48/M60 SERIES TANK, COMBAT FULL-TRACKED 105-MM GUN

TECHNICAL MANUAL; OPERATORS, ORGANIZATIONAL, DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE; BATTLEFIELD DAMAGE ASSESSMENT AND REPAIR

  TM-9-2350-273-BD - Page 139 of 288

TM 9-2350-273-BD
ARMAMENT AND FIRE CONTROL SYSTEMS
Procedural Steps (Cont'd)
CAUTION
Cease firing if length of recoil is excessive or if recoil action
is irregular.
11. Clear bore of main gun.
12. Repeat the recoil exercise (steps 1 through 6).
WARNING
If the gun does not return to battery, do not fire the weapon.
The weapon will be destroyed causing equipment damage
and personnel injuries or cleat h.
13. Record the BDAR action taken. When the mission is completed, as soon as
practicable, repair tank using standard maintenance procedures.
10-8. GUN WILL NOT FIRE; HARD-WIRE BLASTING MACHINE TO MAIN GUN
General Information:
If all other methods to fire the main gun fail, the blasting machine can be wired
directly to the main gun primer to fire the main gun.
Limitations:
Safety circuits are bypassed
Personnel/Time Required:
1 soldier
15 minutes
Material/Tools:
Knife
Tape
Other Options:
Use magneto-type field-phone
Refer to para. 10-9, main gun inoperative; electrical power loss procedure
Procedural Steps:
1. Cut connector off blasting machine cable.
2.
Remove cable from cable clamps.
10-14