COMMUNICATIONS SYSTEM
Personnel/Time Required:
1 soldier
1 hour
Materials/Tools:
Handset, H-189/6R, (each chestplate), or standard CVC helmet
Intercom, Soviet, R-124
Plate, chest, Soviet (one for each control box)
Tape,
electrical.
Wire, 4-conductor, 18-gauge, 5-foot length or cable, telephone, WD-l/TT, 5-foot
length (two required)
Gun, soldering
Solder, rosin-core
Other Option:
Field expedient intercom (refer to para. 11-22).
Procedural Steps:
NOTE
All wires in the R-124 interconnecting cables are soldered
directly to the internal connecting points in the individual
boxes. Use care in removal/installation. Do not disconnect
individual boxes unless absolutely necessary.
1. Remove the R-124 from Soviet vehicle and install in U.S. vehicle.
2.
Wire the H-189/GR handset or CVC helmet using the procedures listed in para.
11-26.
NOTE
Power is obtained in the same manner as listed in step 1 of para. 11-26.
3. Attach the red and white wires from the power cable to the black terminal on the
bottom of the A-1 box of the R-124. Attach the black and green wires from the power
cable to the ground strap on the A-l box. See position 6 in the following illustration.
11-41


Back to Top