TM-9-2350-277-10

CARRIER, M113A3, M577A3, M1059A3, M1064A3, M1068A3 AND M58

TECHNICAL MANUAL; OPERATOR’S MANUAL

  TM-9-2350-277-10 - Page 320 of 889

TM 9-2350-277-10
INSTALL/REMOVE AN/VVS-2(V)1A DRIVER’S NIGHT VISION (ALL EXCEPT M58) — Continued
0034 00
14. Remove night vision power cable from stowage receptacle on master switch panel.
15. Remove cap from driver’s night vision power receptacle and connect vision power cable plug to power receptacle.
STOWAGE
RECEPTACLE
NIGHT VISION
POWER CABLE
REMOVE
1.
Rotate OFF/BRIGHT rotary switch to OFF.
2.
Disconnect vision power cable from driver’s night vision and reinstall power cable connector cap.
3.
Connect night vision power cable to stowage receptacle on master switch panel.
STOWAGE
RECEPTACLE
NIGHT VISION
POWER CABLE
0034 00-5
Change 3
AN/VVS-2(V)1A DRIVER'S NIGHT VISION