0086 01
NOTE
Steps17-19applytoinstallationofdriver’sdisplay(DD)
.
DD may be positioned either on the interior mount in the driver’s compartment or on the
exterior mounting ball. Follow these instructions to install DD to desired position.
17. Loosen T-handle (45) on locking clamp (44) to allow installation of DD (48) on ball on interior mount (43) or exterior
mounting ball (49).
18. Place locking clamp (44) around mounting ball in desired location. Tighten T-handle (45) to secure DD (48).
19. Connect power/data cable (47) to J1 connector (46) on DD (48).
EMPLACING THE MORTAR ON THE M1064A3 CARRIER
1.
Refer to TM 9-1015-250-10.
END OF TASK