OPERATE MDL INVERTER (M1068A3 ONLY) — Continued
0086 02
NOTE
During operations, the inverters can be operated while using external AC power. Switching
between external AC power and the inverters is automatic. There will be a popping noise
when this occurs.
1.
Ensure INVERTER CONTROL switch is in the OFF position.
2.
Turn MASTER SWITCH to ON (WP 0021 00).
3.
Check DC volts meter. It should read above 18.5 volts.
4.
Move INVERTER POWER switch to ON. POWER, BATTERY LOW, and OVERLOAD LED’s will be ON.
NOTE
If POWER LED indicator illuminates, skip Step 5.
5.
Push and engage DC TO INVERTERS circuit breaker.
6.
Push in and release RESET switch to engage the inverters. This allows inverter IN1 to become the primary unit and
inverter IN2 to be the secondary. Only the power LED will remain ON during normal operation.