TM-9-2350-277-20-1

CARRIER M113A3, M577A3, M1059A3, M1064A3, M1068A3 AND M58

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL VOLUME 1 OF 6

  TM-9-2350-277-20-1 - Page 205 of 855

TM 9-2350-277-20-1
GENERATOR MALFUNCTIONS AS INDICATED BY BATTERY/GENERATOR
INDICATOR — Continued
0025 00
B5Y
1.
Remove master switch panel (WP 0260 00 or WP 0261 00).
2.
Measure resistance between harness 12349881 circuit
2/2A (1) between master switch terminal (2) and regulator
plug (3) sockets A (4) and C (5).
3.
Does MSD read 0 ohms?
B5YN
1.
Faulty harness 12349881 circuit
2/2A. Beyond unit maintenance
repair.
2.
Notify supervisor.
B6Y
1.
Replace circuit 6 lead (WP 0356 00, WP 0357 00,
or WP 0358 00).
2.
Verify no faults found.
CY
1.
Has regulator been adjusted?
CYN
1.
Adjust voltage regulator
(WP 0256 00).
2.
Verify no faults found.
002500-6
Change 5