TM 9-2350-277-20-1
GENERATOR MALFUNCTIONS AS INDICATED BY BATTERY/GENERATOR
INDICATOR — Continued
0025 00
C4Y
1.
Remove jumper wire and install harness 12349873
plug on field switch.
2.
Perform MSD/ICE test 67 (MASTER SWITCH ON, engine
OFF) (WP 0124 00). Record reading.
3.
Set up MSD/ICE test 89. See TM 9-4910-571-12&P .
4.
Measure voltage between harness 12349881 jack (1) socket
F(2)andgroundwithMASTERSWITCHON.
5.
Is MSD reading within one volt of MSD reading for MSD/ICE
test 67?
C4YN
1.
Faulty harness 12349881 circuit 1C.
Beyond unit maintenance repair.
2.
Notify supervisor.
002500-9
Change 5