TM 9-2350-277-20-1
GENERATOR MALFUNCTIONS AS INDICATED BY
BATTERY/GENERATOR INDICATOR
0025 00
INITIAL SETUP:
Maintenance Level
Unit
Tools and Special Tools
General Mechanic’s Tool Kit (WP 0926 00, Item 65)
MSD/ICE Test Set (WP 0926 00, Item 61)
Jumper Wire
Personnel Required
Mechanic
Helper (H)
References
WP 0124 00
Equipment Condition
Engine stopped (TM 9-2350-277-10)
Carrier blocked (TM 9-2350-277-10)
Power plant access door open (TM 9-2350-277-10)
Driver’s power plant access panel removed
(WP 0441 00)
T
1.
Perform MSD/ICE test 67 battery voltage (engine at 1200
RPM; service lights on) (WP 0124 00).
2.
Does MSD read more than 29 volts or less than 26 volts?
TN
1.
Go to battery/generator indicator
malfunctions (WP 0051 00).
Y
1.
Does MSD read less than 29 volts?
YN
GO TO
AY
(PAGE 0025 00-2)
2Y
1.
Perform MSD/ICE test 82 generator output voltage (WP 0133 00).
2.
Does MSD read less than 26 volts?
2YN
GO TO
BY
(PAGE 0025 00-3)
3Y
1.
Perform MSD/ICE test 83 generator field voltage (engine at
1200 RPM; service lights on) (WP 0134 00).
2.
Does MSD read within one volt of the reading obtained when
running MSD test 67 in block T above?
3YN
GO TO
CY
(PAGE 0025 00-6)
002500-1
Change 5