TM 9-2350-277-20-1
GENERATOR MALFUNCTIONS AS INDICATED BY BATTERY/GENERATOR
INDICATOR — Continued
0025 00
4Y
1.
Disconnect battery ground strap/lead(s) (WP 0337 00
or WP 0338 00).
2.
Remove harness 12349873 plug (1) from generator jack (2).
3.
Inspect harness plug pins for corrosion or damage.
4.
Is plug free from corrosion and damage?
4YN
1.
Replace harness, see Table of
Contents.
2.
Verify no faults found.
5Y
1.
Replace generator (WP 0255 00).
2.
Verify no faults found.
AY
1.
Measure resistance between regulator housing (1) and
ground. Use MSD.
2.
Does MSD read 0 ohms?
AYN
1.
Remove regulator (WP 0257 00)
and clean ground contact (bolted
surface).
2.
Install regulator (WP 0257 00).
3.
Verify no faults found.
A2Y
1.
Has regulator been adjusted?
A2YN
1.
Adjust voltage regulator
(WP 0256 00).
2.
Verify no faults found.
002500-2
Change 5